期刊文献+

纸带 光纤技术对硫化氢气体测量的初探 被引量:1

<title>Determination of hydrogen sulphide by paper strip-optical fiber technique
在线阅读 下载PDF
导出
摘要 以研制的光导纤维反射分光光度计为仪器,建立了根据浸渍醋酸铅的纸带与硫化氢反应生成黑色硫化铅斑点而改变纸带相对反射率,达到对H2S测量的新方法。测量波长为450nm,测量H2S浓度范围为5×10-8mol/L~1.35×10-6mol/L。方法可用于测量废气中的硫化氢。 <Abstrcat>Based on homemade optical fiber reflectance spectrometer, the concentration of hydrogen sulphide was measured by spectroscopy on the paper strips impregnated with lead acetate. The changes of the relative reflectance of the stain of black lead sulphide on the strips were determined. The used reagents and detective products were stable. The wavelength selected was at 450nm and the concentration range was from 5×10-8 mol·L-1~1.35×10-6 mol·L-1. Hydrogen sulphide in waste gases was measured by this method with satisfactory results.
出处 《分析试验室》 CAS CSCD 北大核心 2002年第4期49-51,共3页 Chinese Journal of Analysis Laboratory
基金 陕西省教委重点科研项目(98JZK15)
关键词 硫化氢气体 测量 光导纤维 纸带 反射光谱 H2S 废气 Optical fiber Paper strip Reflectance spectroscopy Hydrogen sulphide
  • 相关文献

参考文献3

二级参考文献5

  • 1团体著者,分析化学,1986年,397页
  • 2曾北危,环境分析化学,1974年,65页
  • 3阎宏涛,分析仪器,1994年,3期,12页
  • 4李在清,光谱光度测量与标准,1993年,110页
  • 5程介克,痕量分析,1993年,166页