期刊文献+

78例颈椎椎间融合器临床应用的疗效分析 被引量:2

暂未订购
导出
摘要 目的 分析颈椎椎间融合器 (CFC)临床应用的疗效。方法 随访 78例植入CFC的脊髓型颈椎病、外伤性颈椎间盘突出、外伤性颈椎不稳患者 ,观察CFC临床应用疗效。结果 单节段融合率为 10 0 % ,二节段融合率为 94 4 % ,三节段融合率为 6 6 7% ,并发症发生率为 9%。结论 CFC的疗效随融合节段的增加而有所降低 ;钛合金Cage的并发症值得引起重视。
出处 《江苏医药》 CAS CSCD 北大核心 2002年第8期605-607,共3页 Jiangsu Medical Journal
关键词 颈椎 融合器 疗效
  • 相关文献

参考文献6

  • 1[1]Swin PD,Traynelis VS,Menezes AH.A comparative analysis of fusion rates and donor-site morbidity for autogenetic rib and iliac crest bone grafts in posterior fusions.J Neurosurgery,1998,88:255-265.
  • 2[2]Hacker RJ. A randomized prospective study of anterior cervical interbody fusion device with a minimum of 2 years of follow up results.J Neurosurg(Spine 2),2000,93:222-2226.
  • 3[3]Wilke HJ,Kettler A,Goetz C,et al.Subsidence resulting from simulated postoperative neck movements:an in vitro investigation with a new cervical fusion cage.Spine,2000,25:2762-2770.
  • 4[4]Robert JH,Joseph CC,Thomas JG.A prospective randomized multicenter clinical evaluation of an anterior cervical fusion cage.Spine,2000,25:2646-2655.
  • 5[5]Wilke HJ,Kettler A,Claes J.Primary stabilizing effect of interbody fusion devices for the cervical spine:an in vitro comparison between three different cage types and bone cement.Eur Spine J,2000,9:410-416.
  • 6[6]Samandouras G,Shafafy M,Hamlyn P.A new anterior cervical intrumentation system combining an intradical cage with an integrated plate.Spine,2001,26:1188-1192.

同被引文献20

  • 1Sanford EE, Michael JB, Michael A,et al. Robinson anterior cervical fusion: Comparison of the standard and modifiedtechniques[J ]. Spine1994, 19: 660-3.
  • 2Martin GJ, Haid RW, MachMillan M, et al. Anterior cervical discectomy withfreeze-dried fibula allograft: Overview of 317 cases and literature review[J]. Spine,1999, 24(9): 852-8.
  • 3Kozak JA, Heilman AE, O'Brien JP. Anterior lumbar fusion option:technique and graftmaterials[J]. Clin Orthop, 1994, 300: 45-51.
  • 4Closkey F, Parson R, Lee C, et al. Mechanics ofinterbody spinal fusion:analysis ofcritical bone graft area[J]. Spine, 1993, 18:1011-5.
  • 5Hollowell J, Vollmer D, Wilson C, et al. Biomechanical analysis of thoracolumbarinterbody constructs: How important is the endplate[J]? Spine, 1996, 21:1032-6
  • 6Grant JP, Oxland TR, Dvorak MF, et al. Mapping the structural properties of thelmbosacral vertebral endplates [J]. Spine, 2001,26:889-96.
  • 7Silva MJ, Wang C, Keaveny TM, et al. Direct and computed tomography thicknessmeasurements of the human lumbar vertebral shell and endplate [ J ]. Bone, 1994, Jul-Aug,15 (4): 409-14.
  • 8Hall LT, Esses SI, Noble PC, et al. Morphology of the lumber vertebralendplates[J]. Spine, 1998,23(14): 1517-23.
  • 9Lim TH, Kwon H, Jeon CH, et al. Effect of endplate conditions and bone mineraldensity on the compressive strength of the graft-endplate interface in anterior cervicalspine fusion[J]. Spine, 2001, 26: 951-6.
  • 10Samandouras G, Shafafy M, Hamlyn P. A new anterior cervical instrumentation systemcombining an intradical cage with an integrated plate[J]. Spine, 2001, 26:1188-92.

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部