期刊文献+

一种用于超声测温的双超声脉冲发射接收电路的设计 被引量:6

Design of Double Ultrasound Pulse Transmitting and Receiving Circuits Used in Ultrasound Thermometry
在线阅读 下载PDF
导出
摘要 介绍了一种用于热疗法中超声测温的双超声脉冲发射接收电路。电路可以同步产生符合超声测温要求的双超声脉冲,并且能够成功接收放大比较微弱的超声回波信号。提供了实验中的关键波形,说明该电路具有足够的可靠性。 This paper introduces double ultrasound pulse transmitting and receiving circuits used in ultrasound thermometry. Using the circuits, double ultrasound pulses could be made synchronously to satisfy the requirements of ultrasound thermometry, and the weak ultrasound echo signals are received successfully. The crux experiment waveform offered shows that the circuits have high reliability.
出处 《中国医疗器械杂志》 CAS 2002年第4期245-249,285,共6页 Chinese Journal of Medical Instrumentation
关键词 设计 超声 测温 超声发射接收电路 ultrasound, thermometry, ultrasound transmitting and receiving circuits.
  • 相关文献

同被引文献33

  • 1任新颖,吴水才,曾毅.基于组织超声回波时移的无创测温技术及系统设计[J].北京生物医学工程,2005,24(6):428-431. 被引量:4
  • 2EMA S.Ebbini, Claudio Simon.Temperature imaging using diagnostic ultrasound:methods for guidance and monitoring of thermal treatments of tissue[A].Part of the SPIE Conference on Thermal Treatment of Tissue with image Guidance[C].California:SPIE, 1999:150-157.
  • 3WORTHINGTON A E,SHERAR M D.Changes in ultrasound properties of porcine kidney tissue during heating[J].Ultrasound in Med & Biol, 2001, 27(5):673-682.
  • 4SIMON C,VANBAREN P S, EBBINI E.Two-dimensional temperature estimation using diagnostic ultrasound[J].IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control,1998,45(4):1088-1099.
  • 5StevenHolzner.Visual Basic 6技术内幕[M].北京:机械工工业出版社,1999..
  • 6Simon C,VanBaren P, S. Ebbini E. Two-dimensional temperature estimation using diagnostic ultrasound [J]. IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 1998, 45:1088.
  • 7Emad S. Ebbini and Claudio Simon. Temperature imaging using diagnostic ultrasound: methods for guidance and monitoring of thermal treatments of tissue [A]. Part of the SPIE Conference on Thermal Treatment of Tissue with image Guidance, 1999, 3594:150.
  • 8任新颖 吴水才 白燕萍.利用超声回波时移无创检测组织温度方法的研究[A].中国生物医学工程学会.中国生物摘要汇医学工程学会第六次会员代表大会暨学术会议论文编[C].,2004-4.247.
  • 9Bevan PD,Sherar MD.B-scan ultrasound imaging of thermal coagulation in bovine liver:frequency shift attenuation mapping.Ultrasound Med Riol 2001;27(6):809-817.
  • 10Bharat S,Techavipoo U,Kiss M Z,et al.Monitoring Stiffness changes in lesions after radiofrequency ablation at different temperatures and durations of ablation.Ultrasound Med Biol 2005;31(3):415-422