摘要
描述了用于膛口二次燃烧温度测量的原子发射光谱双谱线遥测方法及测温系统 ,并给出了 7.6 2 mm枪膛口二次燃烧温度的测量结果 .测温精度较好 ,相对误差小于 2 % .
This paper describes the telemetry and the system based on atomic emission spectroscopy that can be used to measure transient temperature of the secondary muzzle flash,and gives the temperature measurement results in the secondary muzzle flash of a 7.62mm rifle obtained by using this method.The precision of temperature measurement is superior to 2%. So a new approach is provided for temperature measurement in secondary muzzle flash of large caliber guns.
出处
《弹道学报》
CSCD
北大核心
2002年第2期69-72,共4页
Journal of Ballistics
关键词
二次燃烧
原子光谱遥测
膛口
温度测量
muzzle temperature measurement,spectroscopic,temperature measurement,telemetry