摘要
阐述了大过冷度制冷———高温水蓄冷空调系统原理 ,对该系统中的关键设备过冷器进行了选型和计算。在液———液换热型板式换热器传热特性无资料的情况下 ,根据板式蒸发器的传热特性和管式液———液热交热换热器与管式蒸发器的传热系数的比值来估算板式过冷器的传热系数或传热单元数。实验证明 。
The principle of great supercooling temperature refrigeration--chilled water storage system is expounded.The type and design of supercooling heat exchanger which is a important equipment in this new system are considered.Inthe absence of heat transfer property of plate supercooling heat exchanger,the heat transfer property of plate supercooling heat exchanger is determined according to the heat transfer property of plate evaporator and heat transfer coefficient ratio between tube evaporator and tube supercooling heat exchanger.The experiment results state clearly that the design method is successful.
出处
《建筑热能通风空调》
2002年第4期47-52,共6页
Building Energy & Environment
基金
南京大学人才培养基金项目
关键词
逆流式过冷器
大过度制冷
高温水蓄冷
换热特性
great supercooling temperature refrigeration
chilled water storage
supercooling heat exchanger