期刊文献+

精密微压差计算机数据采集系统测定过氧化氢分解反应速度常数 被引量:1

Measuring Reaction Rate Constant of Hydrogen Peroxide Decomposition Reaction by Computer Data Acquisition System of Accurate Pressure Difference
在线阅读 下载PDF
导出
摘要 报道了用传感器、直流放大器、数据采集存贮器、计算机等组成的精密微压差计算机数据采集系统 ,快速准确地跟踪测定了不同温度时过氧化氢分解反应压力与时间的关系 .计算机绘出的反应体系压差电势随时间变化的曲线物理意义明确 ,重现性好 ;将所采集的数据用计算机编程处理得到的ln(E∞ -Et) -t直线 ,其相关系数为0 .9998。 This paper reports computer data acquisition system of accurate pressure difference, which is composed of accurate pressure difference sensor, direct current amplifier, A/D adapter and computer etc. The system has quickly measured the pressure and time of hydrogen peroxide decomposition reaction at different temperature. The curve plotted by program can represent definitely the tendency which the potential of pressure difference changes with the time. The reappearance of results is good. The covariance of the lineis regressed between (E ∞-E t)and time is 0.9998. By disposition of the above data,the activation energy and reaction rate constant are obtained and its result is satisfactory.
出处 《四川师范学院学报(自然科学版)》 2002年第2期206-209,共4页 Journal of Sichuan Teachers College(Natural Science)
关键词 精密微压差计算机数据采集系统 速度常数 活化能 催化分解反应 反应压力 reaction rate constant accurate pressure difference computer data acquisition system direct current amplifier
  • 相关文献

参考文献6

  • 1复旦大学等.物理化学实验[M].北京:人民教育出版社,1979.
  • 2S Harned.Jour Amer Chem[J].1918,40:1462.
  • 3曲洪洛 张锦桥."H2O2分解动力学"教学实验方法的改进[J].化学通报,1980,(3):37-37.
  • 4覃海错 陈元发 廖井丹.恒温恒压下过氧化氢的动力学测定[J].化学通报,1987,4:55-57.
  • 5徐士良.计算机常用算法(第2版)[M].北京:清华大学出版社,2000.
  • 6WASHBORN E W.International Critical Tables[J].1930,Ⅶ:120.

共引文献3

同被引文献2

  • 1广西师范大学,等五校.物理化学实验[M].桂林:广西师范大学出版社,1991.
  • 2覃海错 陈元发 廖井丹.化学通报,1987,(4):55-57.

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部