摘要
介绍了串联冰蓄冷系统设计中泵能耗的3种节能方法: 串联泵、变频泵和制冷机旁通. 通过对某工程实例的模拟计算,对比分析了这3种方式的节能效果,提出了有效的节能方式.
Three means to save energy in the design of series ice storage system, including secondary pump, variable speed pump and chiller by-pass valve, are discussed and compared by simulation and computation in the paper. Finally, an economical and effective means is proposed.
出处
《上海理工大学学报》
CAS
北大核心
2002年第2期145-148,157,共5页
Journal of University of Shanghai For Science and Technology
关键词
冰蓄冷
串联
串联泵
变频泵
制冷机旁通阀
ice storage system
series system
secondary pump
variable speed pump
chiller by-pass valve