摘要
从设计、安装、管理等方面分析了电气火灾发生的原因和相应的对策 ,着重分析了漏电引起火灾的危害和采取的漏电保护措施 ,对感应雷和雷电反击对弱电设备的损害提出了加装过压保护器和浪涌抑制器的措施。强调了加强安全管理在防止电气火灾中所起的重要作用。
From the design, installation and management the reasons of electric fire and its prevention measures are analyzed. The damage caused by electrical leakage and the adopted protective measures are mainly analyzed. The measures of adding overvoltage protective device and surge controller are proposed according to the damage of induction thunder and lightning reaction to weak devices. At last the important actions of intensifying safety management are emphasized for prevention electric fire.
出处
《山西建筑》
2002年第6期78-79,共2页
Shanxi Architecture
关键词
电气火灾
漏电保护
过电压
等电位连结
electric fire, leakage protection, overvoltage, equipotential connection