分析了 0 0 1× 7阳离子交换树脂用于水处理过程中变红、变棕和粉碎对工作交换容量的不同影响程度。提出了正常使用变红、变棕和非受冻粉碎后的树脂的可使用性与受冻粉碎后工作交换容量的不可恢复性。 [关键词 ]阳离子交换树脂 ;粉碎 ;
The different degrees of the effects of the going red,going orange and breakage in the process of using 001×7 cation exchange resin in water treatment on the working exchange capacity are analysed. The practicality of using the going red,going orange and breaking resin without being frozen in normal service and the irretrievability of working exchange capacity of breaking resin after being frosen are offered.
出处
《工业水处理》
CAS
CSCD
2002年第2期59-59,共1页
Industrial Water Treatment