期刊文献+

全髋关节置换的进展 被引量:3

Advances of total hip arthropalsty
暂未订购
导出
摘要 全髋关节置换是严重髋关节疾病的一种有效的治疗手段 ,近年来取得了很大的发展 ,新技术、新理念不断出现。本文作者对全髋关节置换从假体材料的选择、假体设计到并发症等各方面给予介绍 ,差重对近年来的新观念。
作者 常非 张新
出处 《吉林大学学报(医学版)》 CAS CSCD 北大核心 2002年第3期328-330,共3页 Journal of Jilin University:Medicine Edition
  • 相关文献

参考文献20

  • 1[1]Dorr LD,Wan ZN,Long john DB,et al.Total hip arthroplasty with use of the mental-on-mental articulation [J].J Bone Joint Surg Am,2000,82(6):789-798.
  • 2[2]Oishi CS,Walker RH,Colwell CW Jr.The femoral component in total hip arthroplasty.Six to eight-year follow-up of one hundred consecutive patients after use of a third-generation cementing technique[J].J Bone Joint Surg Am,1994,76(8):1130-1136.
  • 3[3]TenHuisen KS,Martin RI,Klimkiewicz M,et al.Formation and properties of a synthetic bone composite: hydroxyapatite-collagen[J].J Biomed Mater Res,1995,29(7): 803-810.
  • 4[4]Keisu KS,Orozco F,Sharkey PF,et al.Primary cementless total hip arthroplasty in octogenarians.Two to eleven-year follow-up[J].J Bone Joint surg Am,2001,83(3):359-363.
  • 5[5]Barrack RL,Paprosky W,Butler RA,Palafox A,Szuszczewicz Z,Myers L.Patients percepation of pain after total hip arthroplasty[J].J Arthroplasty,2000,15(5): 590-596.
  • 6[6]Soballe K.HA ceramic coating for bone implant fixation[J].Acta Orthop Scand suppl,1993,64(225):1-58.
  • 7[7]Hayashi K,Inadome T,Tsumura H,et al.Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength[J].Biomaterials,1994,15(14):1187-1191.
  • 8[8]Geesink RGT,Hoefnagels NHM.Six-year results of hydroxyapatite coated total hip replecement[J].J Bone Joint Surg Br,1995,79(4):534-547.
  • 9[9]Geesink RG.Clinical,radiological and human histological experience with hydroxyapatite coatings in orthopaedic surgery[J].Acta Orthop Belg,1993,59(1):160-164.
  • 10[10]Woolson ST,Habor DF.Primary total hip repleacement with in-oution of an acetabular component without cement and a femoral component cement: follow-up study at an average of six year[J].J Bone Joint Surg Am,1996,78:698-705.

同被引文献41

  • 1李长有,王禹祥,范广宇.髋臼发育不良性髋关节的三维有限元非线性接触压力分析[J].医用生物力学,2005,20(1):18-24. 被引量:17
  • 2Thomas W, Sehug M. Significance of the position of the endoprosthesis acetabular cup from the biomeehanieal and clinical viewpoint-recommendations for a classification [J].Biomed Tech, 1994, 39 (9): 222-226.
  • 3Kummer FJ, Shah S, Iyer S, et al. The effect of acetabular cup orientations on limiting hip rotation [J]. J Arthroplasty, 1999,14 (4): 509-513.
  • 4Sherepo KM. Biomechanical data regarding the socket-neck orientation of hip endoprosthesis [J]. Ortop Travmatol Protez,1991, (5): 43-45.
  • 5D'Lima DD, Urquhart AG, Buehler KO, et al. The effect of the orientation of the acetabular and femoral components on therange of motion of the hip at different head-neck ratios [J].J Bone Joint Surg [Am], 2000, 82 (3): 315-321.
  • 6Widmer KH, Zurfluh B. Compliant positioning of total hip components for optimal range of motion [J]. J Orthop Res,2004, 22 (4): 815-821.
  • 7Lengsfeld M, Bassaly A, Boudriot U, et al. Size and direction of hip joint forces associated with various positions of the acetabulum [J]. J Arthroplasty, 2000, 15 (3): 314-320.
  • 8Delagoutte P, Mainard D, Dupuy M, et al. Study of loosening and wear of total hip prosthesis. Apropos of a seriesfollowedup over 10 years [J]. Rev Chir Orthop Reparatrice Appar Mot,1991, 77 (1): 25-33.
  • 9Bozic KJ, Freiberg AA, Harris WH. The high hip center [J].Clin Orthop, 2004, 420: 101-105.
  • 10Kim YH, Kim .IS, Cho SH. Strain distribution in the proximal human femur. An in vitro comparison in the intact femur and after insertion of reference and experimental femoral stems [J].J Bone Joint Surg (Br), 2001, 83 (2) : 295-301.

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部