摘要
通过电解或加入掩蔽剂的方法 ,减少Cu2 + 、Mn2 + 、Co2 + 对测定的干扰 ;控制pH值在 6~ 7,温度 6 0~ 70℃的条件下 。
This paper has discussed the gravimetric method with dimethylglyoxime for measurement of niclel in alloy by means of controlling the pH value(pH=6~7)under the thmperature 60~70℃,and through electrolysis or screening agent to reduce the interference of Cu 2+ ,Mn 2+ ,Co 2+