介绍了广东奥林匹克体育场自动喷水灭火系统的设计及调试过程 ,对《自动喷水灭火系统设计规范》(GB5 0 0 84 - 2 0 0 1)第 6 2 3条的规定进行了探讨 ,并根据调试情况对体育场增压泵流量提出了符合工程实际的确定值。
The courses of design and trail run of automatic sprinkling fire system in Guangdong Olympic Center are presented. The guideline in stipulation 6 2 2 in the Design Norm of Automatic Sprinkling System (GB50084-2001) is discussed; the rational discharge of the lift pump for the stadium is reported according to the practice in trail run.