摘要 本文以正交实验理论为指导 ,对各种不同的水储冷、释冷过程 ,尤其对水池取水口处水温上升的影响因素进行了实验研究。通过大量的实验及数据处理分析 ,得出利用消防水池进行蓄冷空调的方式是可行的。 This paper , based on the theory of just meet, had established an test model , in which, cold accumulating and cold releasing process could be completed and tested. Especial attention were paid on the factors by which the temperature rising rate at cistern exit was affected. According to the calculating work, testing work, date processing and analyzing , conclusions below could gotten: Fire cisterns which are used to store water can also be used in cold storage air conditioning system. The rate of temperature rising in the exit is mainly affected by the number of separate wall inside the pool, the water velocity at the entrance, etc.
出处 《河北建筑科技学院学报》 2001年第3期13-16,共4页 Journal of Hebei Institute of Architectural Science & Technology
关键词 消防水池 蓄冷空凋 模型实验 fire cistern cold storage air conditioning system model experiment
  • 相关文献

参考文献2

  • 1Hamdan MG. An experimental study ofstratified thermal storage under variable inlet temperature for different inlet designs [J]. Int J Heat Mass Transfer, 1992, 35 (8): 1927-1934.
  • 2Cai Letal. Turbulent buoyant flows into a two dimensional storage tank [J]. Int JHeat Mass Transfer, 1993, 36 (1): 4247-4256.

同被引文献22

  • 1刘雪玲,李宁.低温地热水源热泵供暖技术[J].煤气与热力,2004,24(10):567-569. 被引量:17
  • 2韩学廷,秦庚仁,张伟捷,陈贵堂,张中进.论空调制冷系统储供能系数的概念[J].河北煤炭建筑工程学院学报,1994,11(2):34-37. 被引量:1
  • 3赵振南.传热学[M].北京:高等教育出版社,2002..
  • 4J E Bose. Advances in ground source heat pump systems an international overview[A]. In: 7th International Energy Agency Heat Pump Conference. Beijing: China Architecture & Building Press, 2002:313-324.
  • 5D Cane, B Clemes and A Morrison. Experiences with commercial ground-source heat pumps . ASHRAE Journal, 1996, (7):31-36.
  • 6D Cane, J M Garnet. Update on maintenance and service costs of commercial building ground-source heat pump systems . ASHRAE Transactions, 2000, 106(1):399-407.
  • 7M A Martin, M G Madgett, and P J Hughes. Comparing maintenance costs of geothermal heat pump systems: preventive maintenance actions and total maintenance Costs . ASHRAE Transactions, 2000, 106(1):408-423.
  • 8W H Leong, V R Tarnawski, and A Aittomaki. Effect of soil type and moisture content on ground heat pump performance. Int. J.Refrig., 1998, 21(8):595-606.
  • 9F J Lenarduzzi, C B H Cragg, H S Radhkrishna. The importance of grouting to enhance the performance of earth energy systems . ASHRAE Transaction, 2000, 106(1):424-434.
  • 10李新国,张启.地热热泵调峰供暖系统的热力及经济分析[J].太阳能学报,1997,18(2):146-151. 被引量:15

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部