本文以正交实验理论为指导 ,对各种不同的水储冷、释冷过程 ,尤其对水池取水口处水温上升的影响因素进行了实验研究。通过大量的实验及数据处理分析 ,得出利用消防水池进行蓄冷空调的方式是可行的。
This paper , based on the theory of just meet, had established an test model , in which, cold accumulating and cold releasing process could be completed and tested. Especial attention were paid on the factors by which the temperature rising rate at cistern exit was affected. According to the calculating work, testing work, date processing and analyzing , conclusions below could gotten: Fire cisterns which are used to store water can also be used in cold storage air conditioning system. The rate of temperature rising in the exit is mainly affected by the number of separate wall inside the pool, the water velocity at the entrance, etc.