期刊文献+

臭氧发生管的设计及其稳定性研究 被引量:6

A Study on the Stability and the Design of the High-effciency Ozone Cell
在线阅读 下载PDF
导出
摘要 结合高效变频臭氧发生器的研制 ,就如何提高发生管的臭氧产量、浓度、产率等性能参数进行了分析 ,从逆变高压电源、介电体、冷却系统等方面探讨提高臭氧发生器稳定性的设计方法 .研究结果表明 ,采用某有机高分子材料为介电体的臭氧发生管技术性能良好 .当以空气为气源时 ,单管臭氧产量 36 .3g/h ,臭氧浓度 2 9.0 g/m3,臭氧产率 178.0g/(m2 ·h) ,电耗 17.5kW·h/kgO3. To meet the demand of more efficient and more stable ozone cell of ozone generator with higher yields,the main relevant factors are analyzed based on experiments and practice;and the principle and design of high efficiency ozone cell are studied in this paper.And the main functional parameters of ozone cell such as the ozone output,the ozone concentration and ratio production are discussed and compared with the power supply,the dielectric material and the cooling system.Particularly,some new macromolecular material is used as the dielectrics and the experiment results indicate that some important functional parameters of it are better than those of glass,which is used as conventional dielectrics.For one ozone cell,the ozone output,ozone concentration,ozone ratio production and energy consumption would be 36.3g/h,29.0g/m 3,178.0g/(m 2·h) and 17.5kW·h/kgO 3 respectively when air is used for the feed gas.
出处 《河海大学常州分校学报》 2002年第1期1-5,共5页 Journal of Hohai University Changzhou
关键词 自氧发生器 臭氧发生管 介电体 电晕放电 稳定性 结构性能 冷却系统 ozone generator ozone cell dielectric corona discharge