期刊文献+

焚硫炉火管废热锅炉的副线设计——兼论废热锅炉面积富裕系数 被引量:2

Bypass design of fire tube waste heat boiler after sulphur furnace--simultaneous discussion on redundancy of waste heat boiler heating surface
在线阅读 下载PDF
导出
摘要 推导出火管废热锅炉的面积富裕系数、系统生产负荷率、主线率 3者之间的解析关系式 ,利用该公式可以确定废热锅炉副线设计的气量范围。认为现有的焚硫废热锅炉的面积富裕系数取值普遍偏大。 Analytical relations between redundancy of heating surface, operating duty ratio and mainstream ratio of fire tube waste heat boiler are deducted. Application of the equation can determine the design bypass ratio of waste heat boiler. It is considered that present waste heat boilers after sulphur burner are mostly too higher in their redundancy of heating surface. A specific method for detecting the actual redundancy of heating surface of existent waste heat boiler is offered.
作者 汤桂华
机构地区 南化集团设计院
出处 《硫酸工业》 CAS 2001年第6期23-26,共4页 Sulphuric Acid Industry
关键词 焚硫炉 火管废热锅炉 副线率 受热面积富裕系数 负荷率 解析关系式 sulphur furnace fire tube waste heat boiler bypass ratio redundancy of heating surface operating duty ratio analytical relation