讨论分析了当前采用的供热系统量调节公式在计量供热系统中的适用性 ,提出了修正公式。结合具体算例 ,比较了两公式对不同工况的计算所引起的回水温度、散热量的偏差 ,指出在计量供热系统中应使用修正后的量调节公式。
Discusses the applicability of the existing flow adjustment formula for heating systems. Offers a modified formula through an analysis of the computational temperature difference of radiator. Compares the deviations of the return water temperature and heat emission calculated by the two formulas in different example conditions, suggesting that the modified formula is preferable to be adopted in design of the heat metering systems.
出处
《暖通空调》
北大核心
2001年第6期112-114,共3页
Heating Ventilating & Air Conditioning
关键词
计量供热
运行调节
量调节公式
heat metering, operational adjustment, flow adjustment formula