期刊文献+

体育馆计算上座率的确定及其对空调系统的影响 被引量:8

Calculated attendance and its influences on the air conditioning system in gymnasiums
在线阅读 下载PDF
导出
摘要 调查分析了北京地区体育馆上座情况 ,得出了非满座情况下的人员分布规律。对不同上座率下的负荷进行了比较。提出计算上座率的概念 ,用计算流体动力学 (CFD)技术对不同上座率下观众席温度分布进行预测和评价 ,得到了符合最佳技术经济条件的计算上座率。 Investigates and analyses the attendance of audiences in gymnasiums in Beijing, derives the characteristics of the audience distribution under conditions of partial attendances. Proposes a calculated-attendance concept, evaluates and numerically simulates the temperature distribution of the audience area under different attendance rates, recommends the calculated-attendance-rate conforming with the optimum efficiency.
出处 《暖通空调》 北大核心 2001年第6期47-50,共4页 Heating Ventilating & Air Conditioning
关键词 体育馆 冷负荷 上座率 流体动力学 空调系统 gymnasium, cooling load, attendance rate, calculated attendance rate, CFD
  • 相关文献

参考文献4

二级参考文献5

  • 1Xu Weiran,学位论文,1998年
  • 2Chen Qingyan,Energy Buildings,1998年,28卷,137页
  • 3Said M N A,ASHRAE Transactions,1995年,101卷,1期,104页
  • 4Chen Qingyan,ASHRAE Transaction,1990年,96卷,1期,564页
  • 5Chen Qingyan,Indoor Airflow,Air Quality and Energy Consumption of Buildings,1988年

共引文献89

同被引文献48

  • 1张宇翔,赵立华,陈卓伦,吴怡青.二次回风空调系统控制与节能[J].南方建筑,2010(3):90-92. 被引量:5
  • 2熊和平,彭宝荣.我国体育产业市场的现状及其发展策略[J].武汉体育学院学报,2005,39(1):33-35. 被引量:19
  • 3王钊.珠海机场候机楼空调设计(一)[J].制冷,1996,15(2):24-27. 被引量:1
  • 4李艳,王炤文.江南大学体育馆工程空调系统设计[J].制冷与空调,2007,7(3):90-93. 被引量:3
  • 5.非典防治常识:中央空调为何不安全[N].北京晨报,2003-05-06.
  • 6Hayashia T,Ishizub Y,Kato S,et al.CFD analysis on characteristics of contaminated indoor air ventilation and its application in the evaluation of the effects of contaminant inhalation by a human occupant [J].Build and Envir,2002,37(3):219-230.
  • 7Brohus H,Nielsen P V.Contaminant distribution around persons in rooms ventilated by displacement ventilation [A].Roomvent'94 [C].Cracow,Poland:1994.293-312.
  • 8Murakami S,Kato S,Nagano S,et al.Diffusion Characteristics of Airborne Particles with Gravitational Settling in a Convection-Dominant Indoor Flow Field [J].ASHRAE Trans,1992,98(1) :82-97.
  • 9Kato S,Murakami S,Kobayas H.New Scales For Evaluating Ventilation Efficiency as Affected by Supply and Exhaust Openings Based on Spatial Distribution of Contaminant [A].12th Int Symp on Contamination Control [C].Japan:Japan Air Cleaning Association,1994.341-348.
  • 10Zhao B,Li X,Yan Q.A simplified system for indoor airflow simulation [J].Build and Envir,2003,38(4):543-552.

引证文献8

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部