摘要
目的 探讨超速起搏预适应 (PP)对缺血再灌注心肌梗塞范围及室性心律失常发生率的影响。 方法 2 4只健康家兔随机分为缺血再灌注损伤组 (IR组 )和超速起搏预适应组 (PP组 ) ;测定两组梗塞区、危险区的心室重量 ,计算梗塞范围 ,并对室性心律失常发生率进行评分。 结果 (1)心脏 IR组和 PP组梗塞区检测结果 :梗塞区心室重量为 44 1.3± 31.0 3m g比 175 .7± 41.8m g,梗塞范围为 42 .4%± 3.6 %比 16 .7%± 1.2 % ,差异有显著性(P<0 .0 1)。 (2 ) IR组和 PP组室性心律失常发生率评分为 3.6 7± 0 .89比 1.83± 0 .72 ,差异有显著性 (P<0 .0 1)。 结论 (1) PP降低心肌急性缺血再灌注时梗塞范围 ;(2 ) PP降低心肌急性缺血再灌注时室性心律失常的发生。
Objective\ To investigate the protective effect of the overdriving pacing preconditioning.\ Methods\ 24 rabbits were devided into ischemia\| reperfusion group(IR group) and overdriving pacing preconditioning group(PP group).\ The infarct size(IS), area at risk(AAR) and the appearance of ventricular arrhythmias of the two groups were examined.\ Results\ (1)The weight of infarct size of the two groups were 441 3±31 03 mg vs 175 7±41 8 mg, IS/AAR(%) were 42 4%±3 6% vs 16 7%±1 2%(P<0 01).\ (2)The appearance of ventricular arrhythmias of the two groups were 3 67±0 89 vs 1 83±0 72(P<0 01).\ Conclusion\ (1)PP could alleviate the injury of ischemic myocardium and reduce the myocardial infarct size; (2)PP could reduce the occurence of ventricular arrhythmias.\;
出处
《福建医科大学学报》
2001年第3期244-246,249,共4页
Journal of Fujian Medical University
基金
福建省教育厅科研基金资助项目 ( K2 0 0 5 9)
关键词
心肌梗塞
心律失常
心肌再灌注
缺血预处理
心肌
家兔
myocardial infarct
arrhythmias
myocardial reperfusion
ischemic preconditioning,myocardial
rabbit