期刊文献+

X线摄影、彩色多普勒超声和立体定位穿刺对早期乳腺癌的诊断价值 被引量:55

The value of mammography, color Doppler ultrasound and biopsy in diagnosis of early breast cancer
原文传递
导出
摘要 目的 探讨X线摄影、彩色多普勒超声 (简称彩超 )和立体定位穿刺对早期乳腺癌的诊断价值 ,提高其诊断率。方法  5 5例早期乳腺癌和 2 5例乳腺良性病变均行两侧X线摄影、彩超检查 ,再经立体定位穿刺 ,作病理学检查。结果 在 5 5例早期乳腺癌中 ,X线钼靶摄影诊断早期乳腺癌4 5例 ,其敏感性和特异性分别为 82 0 %和 88 0 % ,准确性为 83 8% ;彩超诊断早期乳腺癌 4 3例 ,其敏感性和特异性分别为 78 2 %和 84 0 % ,准确性为 80 0 % ;立体定位穿刺诊断早期乳腺癌 5 3例 ,其敏感性和特异性分别为 96 4 %和 92 0 % ,准确性为 95 0 % ,无假阳性。综合影像诊断早期乳腺癌 5 4例 ,其敏感性和特异性分别为 98 2 %和 96 0 % ,准确性为 97 5 %。结论 X线摄影、彩超和立体定位穿刺联合应用 ,可提高早期乳腺癌诊断的敏感性和准确性。 Objective To study the diagnos tic value of mammography, color Dopp ler ultrasound and biopsy in early breast cancer and to evaluate its diagnostic accuracy. Methods 55 patients with breast cancer an d 25 patients with benign breast masses, proved pathologically, were checked by mammogra phy, color Doppler ultrasound and biopsy. Results Mammography demonstrated bre ast cancer in 45 cases, the sensitivity and specificity were 82.0% and 88.0%, re spectively, with the accuracy of 83.8%; Color Doppler ultrasound revealed breas t cancer in 43 cases, the sensitivity, specificity and accuracy were 78.2%, 84 .0% and 80.0%; Biopsy demonstrated breast cancer in 53 cases, the sensitivity, specificity and accuracy were 96.4%, 92.0% and 95.0%. When ultrasound, mammagrap hy and biopsy were combined together, the sensitivity, specificity and accuracy were 98.2%, 96.0% and 97.5%. Conclusion Mammography, color Dopp ler ultrasound combined with biopsy can increase the diagnostic sensitivity and accuracy of ear ly breast cancers.
出处 《中华放射学杂志》 CAS CSCD 北大核心 2001年第10期782-784,共3页 Chinese Journal of Radiology
关键词 乳腺癌 X线摄影 彩色多普勒超声 诊断 立体定位技术 活组织检查 针吸 Breast neoplasms Mammography Ultrasonography, mammary Stereotaxic technigues Biopsy,needle Evaluation studies
  • 相关文献

参考文献4

二级参考文献4

共引文献143

同被引文献222

引证文献55

二级引证文献313

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部