摘要
南澳风电场装机容量已达 5 3.8MW,约占汕头地方电网容量的 7% ,近期具备开发条件的风资源在 30 0 MW以上。因此 ,风力发电是否对电能质量有明显的影响受到人们的关注 ,该文介绍了谐波测量与分析结果。
The installed capacity of wind power plants in Nanao Island has been up to 53.8MW, which is approximately 7% of the capacity of Shantou electric power system. In the near future, the wind power resource that is feasiblt to be utilized is estimated over 300MW.Therefore the influence of the wind power plants on the power supply quality is concerned extensively.This paper gives some results of the harmonic testing and analysis.
出处
《电网技术》
EI
CSCD
北大核心
2001年第11期80-82,共3页
Power System Technology