摘要
导电胶中存在的痕迹量的Na+ 和Cl- 对于胶的正常使用有不利的影响。用 18mΩ的超纯水将它们从胶体中萃取出来 ,用原子吸光分光光度法和离子色谱法分别测定溶液中的Na+ 和Cl- 。
Na +and Cl - in minute quantity is not advantageous to the normal application of electrically conductive adhesives. Ultra purified water of 18mΩ was used to abstract Na +and Cl - from the adhesives. Na +and Cl - in the solution could be measured with AA Spectum and Ion Exchange Chromatography.
出处
《中国胶粘剂》
CAS
2001年第3期35-37,共3页
China Adhesives
关键词
导电胶粘剂
原子吸收分光光度法
离子色谱法
钠离子
氯离子
electrically conductive adhesives
AA spectrum
ion exchange chromatography
sodium ion
chlorine ion