摘要
利用微机计算了典型氨两级压缩制冷系统循环中压缩机功耗与冷凝温度的关系 .根据对两个工业制冷装置的实地测试和分析 ,提出制冷装置在部分负荷时 ,冷却水系统的节能调节原则 .
The relationship between power consumption of compressors and condensing temperatures is calculated under a typical cycle of ammonia two stage compression refrigeration,by means of personal computers.Based on field measurement on two industrial refrigerating plants,the principles of adjusting cooling water system are proposed under part load conditions.These principles can be used to conduct the operation and adjustment of current cooling water systems,and to optimize the design of new refrigeration systems.
出处
《集美大学学报(自然科学版)》
CAS
北大核心
2001年第3期228-232,共5页
Journal of Jimei University:Natural Science
基金
农业部青年重点课题资助项目 (渔 85 - 93-新 0 8)