摘要 本文以秦山核电工程多堆厂址为例 ,当正常运行工况下年均气态放射性污染物浓度分布采用极坐标方式表示时 ,提出了 2种多源时污染物浓度迭加的计算方法。方法 1是直接根据各污染源对网格点浓度贡献进行迭加 ,具有可靠的精度。方法 2是建立一个等效源 。 As an example of multi reactor sites of Qinshan nuclear power project, two methods are developed for overlapping concentrations caused by normal emission of multi source when concentrations of airborne radioactive contaminants expressed in polar coordinate.The first method is to calculate concentrations according to the concentration contribution of various sources to grids,with good accuracy.The second method supposes that concentration distribution would be caused by an equivalent source in the case of centralized distribution of sources.
作者 姚仁太
出处 《辐射防护通讯》 2001年第1期7-10,37,共5页 Radiation Protection Bulletin
关键词 浓度迭加 大气弥散 核电厂 气态放射性污染物 厂址选择 环境影响评价 浓度分布 Multi reactor sites Concentration overlapping Atmospheric dispersion
  • 相关文献

参考文献6

  • 1秦山核电公司 上海核工程研究设计院.秦山核电厂环境影响报告书(试运行阶段)[M].-,1999..
  • 2核电秦山联营公司.秦山核电二期工程环境影响报告书(设计阶段)[M].-,1995..
  • 3国家环保总局.核电厂环境影响报告书的内容和格式.NEPA-RG1[M].,1988..
  • 4国家核安全局.核电厂厂址选择及评价的人口分布问题.HAF0104[M].,1987..
  • 5杨胤,陈晓秋,丁近厚,赵晖,席小军,李红生.基于微机的核设施环境评价软件包——NGAS、NLIQ、NACC、NRED[J].辐射防护通讯,1995,15(2):1-9. 被引量:1
  • 6秦山第三核电有限公司.秦山三期(重水堆)核电站工程环境影响报告书(设计阶段)[M].,1998..