摘要
该文对安装在华能大连电厂二期工程 2× 35 0MW机组锅炉的三井巴布科克低NOx 旋流燃烧器的设计特点进行了剖析 ,结合锅炉燃烧优化试验对低NOx 旋流燃烧器的性能进行评价 ,对存在的问题进行了探讨。图 2表
The paper presents on analysis of the design features of the MITSUI Babcok low NO x whirling type combustor, installed during the 2×350MW second stage project of Huaneng Dalian Power Plant. An appraisal of its properties, carried out in connection with combustion optimization tests, is reported on, together with a discussion of its shortcomings. Figs 2 and tables 2
出处
《发电设备》
2001年第4期1-4,16,共5页
Power Equipment
关键词
燃煤锅炉
低NOx旋流燃烧器
燃烧
优化
电厂
coal burning boiler
low NO x
whirling type combusor
combustion optimization