期刊文献+

HIRFL-CSR电子冷却装置高精度螺线管线圈制作及磁场测量 被引量:6

Manufacture and magnetic field measurement of high precision solenoid coils for HIRFL-CSR electron cooling device
在线阅读 下载PDF
导出
摘要 采用特殊工艺制作了 HIRFL-CSR电子冷却装置冷却段高精度螺线管线圈 ,两个产生反向磁场的线圈同轴、平行地放置在特制的测量装置上 ,高精度霍尔探头位于测量装置中心平面上 ,探头测量面与测量装置轴线重合 ,测量单个线圈磁场的横向分量 ,调节线圈几何轴相对于测量装置轴线的夹角 ,测得线圈磁轴的偏角小于 1× 1 0 -3。 The prototypes of high precision solenoid coils in electron cooling device of HIRFL CSR were fabricated by special techniques. Two coils were placed in two parallel, concentric planes, the lower coil was fixed, and the upper coil can rotate concentrically. The transverse component of magnetic field of each coil was measured with the high resolution Hall sensor. The deviation between magnetic axis of coils and geometric axis of reference plane was less than 1×10 -3 after adjustment. The device meets the equirement of a magnetic field with a depth of parallelism better than 1×10 -4 .
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2001年第5期649-653,共5页 High Power Laser and Particle Beams
基金 国家重大科学工程 H IRFL-CSR冷却储存环项目资助
关键词 线圈 磁场平行度 磁场测量 高精度螺线管 HIRFL-CSR 霍尔探头 coil magnetic field parallelism magnetic field measurement high precision solenoid
  • 相关文献

参考文献5

二级参考文献5

  • 1[2]Schottky W. Uber Spontane Stromschwankungen in Verschiedenen Elecktrizittsleitern[M]. Annalen der Physik, 1918 57: 541.
  • 2[1]Berhard Schlitt. Schottky Mass Spectrometry at the Heavy Ion Storage Ring ESR[Z]. GSI, DISS, 1997, 97-01.
  • 3Parkhomchuk V V.New insights in the theory of electron cooling[].Nuclear Instruments and Methods.2000
  • 4Dikansky N S,Kudelainen V I,Lebedev V A,et al.Ultimate possibilities of electron cooling[]..1988
  • 5Bosser J,Carli C,Chanel M,et al.On the optimum dispersion of a storage ring for electron cooling with high space charge[].Nuclear Instruments and Methods.2000