期刊文献+

应用感光密度仪对六种医用X线胶片感光特性的测试与对比分析

A comparative study of the sensitive properties of six kinds of medical x-ray film with a sensitometer
暂未订购
导出
摘要 目的:对比分析六种医用X线胶片的感光特性。方法:采用柯达、柯尼卡、爱克发、阿尔梅、富士和乐凯X线胶片。用相同的感光量分别感光,同样的冲洗条件加工制成感光光楔照片,经密度仪扫描测量,获得感光特性数据进行对比分析。结果:柯尼卡、柯达、阿尔梅X线胶片的感光特性依次为优。爱克发、富士、乐凯胶片的感光特性基本近似。结论:量化掌握X线胶片的感光特性,有助于合理使用X线胶片,调整摄影因素,提高X线照片影像质量。 Objective: To compare the sensitive properties of s ix kinds of medical X-ray film.Methods:The KODAK,KONICA,AERMEI,AGFA,F UJI and LUCKY X-ray films were used for test. With same dose of exposure and sam e processing conditions the film strips were developed.The data on sensitive pro perties which acquired by scanning and measuring the film strips with a sensitometer were analysed comparatively.Results:The sensitive properties of KONICA,KODAK,AERMEI X-ray film were of good quality in decreasing order.T he AGFA,FUJI,LUCKY were simila r to each other,and next to the former ones.Conclusion: To quanti fy the sensitive properties of films is useful in choosing X-ray films,adjusting the variable radiographic factors and then improving the images quality of X-ray films.
出处 《重庆医科大学学报》 CAS CSCD 2001年第3期307-309,共3页 Journal of Chongqing Medical University
关键词 X线胶片 感光特性 密度 测试 X-ray film Sensitive property Density Test
  • 相关文献

参考文献8

  • 1屠惠霖.医用X线胶片特性与应用(第1版)[M].北京:中国轻工业出版社,1986.1-26.
  • 2周仲.X检查技术学(第一版)[M].上海:上海科学技术出版社,1986.16-20.
  • 3李桂兰 柳祥庭.X线胶片照相性能测定[J].胶片技术应用,1990,5(1):5-7.
  • 4燕树林.X线胶片特性曲线的制作与应用[J].感光材料,1982,3(4):29-31.
  • 5李桂兰,胶片技术应用,1990年,5卷,1期,5页
  • 6周仲,X检查技术学,1986年,16页
  • 7屠惠霖,医用X线胶片特性与应用,1986年,1页
  • 8燕树林,感光材料,1982年,3卷,4期,29页