摘要
论述了电磁流量计在实际使用中出现的仪表测量值与应用参比值不符的检查方法 ,包括示值偏差的原因分析、检查流程 。
The investigating methods to the discrepancy between practical measurement and the reference value of electromagnetic flowmeter are expounded. These methods include analyzing deviation of indicating values and checking process. Several examples are also given.
出处
《自动化仪表》
CAS
北大核心
2001年第5期32-35,共4页
Process Automation Instrumentation
关键词
电磁流量计
测量值
应用参比值
偏差分析
Electromagnetic flowmeter Measurement Reference value in operation Analysis on deviation