摘要
对除氧头主要内件———起膜管的试验进行分析 ,论证了起膜管的最佳结构型式。针对水膜式热力除氧器运行中存在的问题 ,提出了改造的具体实施方法 ,为电厂水膜式热力除氧器的改造提供了新思路。
An analysis was conducted of the testing of a water-membrane generating pipe, the major internal element of a deaerator head. The optimum type of the pipe structural design has also been devised and demonstrated. Concerning some specific problems encountered during the operation of the water-membrane type thermal deaerator the authors have proposed a modification scheme, thus providing a new approach for the retrofit of the above type of deaerator commonly used in power plants.
出处
《热能动力工程》
EI
CAS
CSCD
北大核心
2001年第3期343-344,共2页
Journal of Engineering for Thermal Energy and Power
关键词
热力除氧器
起膜管
水模式
汽轮机
电厂
deaerator, water membrane generating pipe, modification