期刊文献+

基于广义d_k-q_k旋转坐标变换的谐波电流检测方法 被引量:24

A HARMONIC CURRENT DETECTION METHOD BASED ON A GENERALIZED dqk COORDINATE TRANSFORM
在线阅读 下载PDF
导出
摘要 本文提出三相电路广义 dk-qk 旋转坐标变换理论 ,发展出一种任意次谐波电流的检测方法。所谓广义 dk-qk旋转坐标 ,系指以第 k次待检测谐波电流角频率 kω旋转的两相坐标系统。通过广义坐标变换 ,第 k次谐波电流在dk-qk 坐标系内成为与角频率无关的直流分量 ,从而可通过低通滤波及坐标反变换的方法将其检测出来。该方法具有无论三相电路电压是否畸变 ,理论上都能准确地检测出任意次谐波电流的优点 ,并可用于基波有功和无功电流的检测。因此 ,它可应用于电力系统故障检测、保护和电力有源滤波器谐波电流检测中。 The paper proposes a generalized dq k coordinate transform for three phase circuits,develops a novel method of current detection based on it.The so called dq k generalized coordinate is defined as two phase coordinate frame rotated at the angle frequency kω of the kth harmonic current.By the rotated coordinate transform,the kth harmonic current in three phase circuit becomes a dc component,so it can be filtered easily by a low pass filter and detected.In theory this method can effectively and accurately detect the fundamental current,its active and reactive components and any term harmonic current component of three phase circuit no matter what there are harmonic voltages in three phase circuit.Therefore it can be widely applied to fault detection,protection for power system and active power filter.
出处 《电力系统及其自动化学报》 CSCD 2001年第3期25-29,共5页 Proceedings of the CSU-EPSA
关键词 电力系统 广义dk-qk旋转坐标变换 谐波电流检测 无功功率补偿 Generalized dq k coordinate transform, Harmonic current detection, Three phase circuits
  • 相关文献

参考文献6

  • 1张莜华 林莘.滤波技术[M].北京:人民邮电出版社,1994..
  • 2杨君,王兆安.三相电路谐波电流两种检测方法的对比研究[J].电工技术学报,1995,10(2):43-48. 被引量:131
  • 3Peng F Z,IEEE PESC'97,1997年,2卷,1089页
  • 4Luo Shiguo,IEEE Trans Ind Electrion,1995年,42卷,1期,85页
  • 5扬君,电工技术学报,1995年,10卷,2期,43页
  • 6张莜华,滤波技术,1994年

二级参考文献2

  • 1王兆安,电工技术学报,1992年,3期
  • 2李民,电力电子技术,1992年,2期