双压再热蒸汽循环的IGCC变工况性能 被引量:3

Off-Design Performance of IGCC with Dual Pressure and Reheat Steam Cycle
在线阅读 下载PDF
导出
摘要 介绍了 IGCC蒸汽侧采用双压再热循环时再热回路的合理选定。叙述了 IGCC的变工况模型和计算得到的变工况性能及其分析 ,指出调节压气机 IGV时 ,能与一般联合循环一样改善 IGCC的变工况性能。图1 0参 The reasonable selection on reheat roop for steam side of IGCC with dual pressure reheat cycle was discribed. The IGCC off design perpormance model, calculation results and analysis were discribed too. It pointed out that like general combined cycle, IGCC off design performance can be improved by adjusting the compressor's IGV. Figs 10 and refs 6.
机构地区 清华大学热能系
出处 《动力工程》 CSCD 北大核心 2001年第2期1156-1160,共5页 Power Engineering
关键词 IGCC 双压再热 变工况 IGV调节 蒸汽循环 燃气轮机 IGCC dual pressure and reheat off design performance IGV ddjusting
  • 相关文献

参考文献4

二级参考文献1

  • 1赵士杭.联合循环中余热锅炉与汽轮机的滑压运行[J]热能动力工程,1992(03).

共引文献9

同被引文献24

  • 1徐钢,林汝谋,邵艳军,金红光.燃气轮机建模的通用性和精细性研究[J].中国电机工程学报,2005,25(21):106-111. 被引量:24
  • 2黄伙基.余热锅炉蒸汽系统的优化配置及其变工况运行特点[J].中国科技信息,2006(4):110-111. 被引量:8
  • 3刘向杰,殷冲,侯国莲,张建华.联合循环电厂余热锅炉的监督预测控制策略[J].中国电机工程学报,2007,27(20):52-58. 被引量:9
  • 4JOHNSON M S. Prediction of gas turbine on - and off - design perfor- Mance when firing coal - derived syngas[J]. Journal of Engineering for Gas Turbines and Power, 1992,114(4) :380 - 385.
  • 5JOHNSON MARK SCOTT, PJ. D. The effects of gas turbine characteristics on integrated gastication conrbined - cycle power plant performance [D]. Stanford: Stanford Universty,1990.
  • 6朱宝田,徐越.整体气化联合循环(IGCC)动力岛变工况性能研究[R].会议记录ID:6332973,西安:国家电力公司热工研究院,2001.
  • 7中国IGCC示范项目可行性研究课题组.整体煤气化联合循环(IGCC)发电示范项目技术可行性研究.内部报告[M].1998.
  • 8Christoph Koch, Frank Cziesla, George Tsatsaronis. Optimization of combined cycle power plants using evolutionary algorithms [ J ]. Chemical Engineering and Processing ,2007,46 ( 3 ) : 1151 - 1159.
  • 9L. Jiang, R. Lin, H. Jin, et al. Study on thermodynamic characteristic and optimization of steam cycle system in IGCC [ J ] , Energy Conversion and Management, 2002,43 (9-12) :1339-1348.
  • 10JOHNSON M S. Prediction of gas turbine on-and off-design perfor-Mance when firing coal-derived syngas [ J ]. Journal of Engineering for Gas Turbines and Power, 1992, 114(4) :380-385.