摘要 石英晶体微天平 (QCM )作为一种高灵敏度的质量检测手段 ,已经用于金属材料大气腐蚀动力学及其环境因素和缓蚀剂存在的影响规律的研究 。 The application of quartz crystal microbalance (QCM) in the study of atmospheric corrosion is reviewed.QCM is available to measure mass changes of a nanogram order and has widely been used for in situ investigations of atmospheric corrosion.The effects of environmental factors, corrosive gas constituents and gas phase inhibitors on the atmospheric corrosion mechanism of metal materials have been studied with QCM.In the recent years, the atmospheric corrosivity probe based on QCM techniques has been developed.The characteristics and developing trend of QCM for atmospheric corrosion investigation and monitoring are analyzed and discussed.