期刊文献+

用于微光探测器的天文杜瓦

COOLED DEWARS FOR ASTRONOMICAL DETECTOR APPLICATION
在线阅读 下载PDF
导出
摘要 综述了天文用CCD激光探测器对天文杜瓦的要求,介绍了研制的TWD型杜瓦的特点和试验情况。试验结果表明,在无探测腔时,Ⅱ型和Ⅲ型杜瓦容器的技术指标分别达到:有效容积2.5L和1.25L;质量2.05kg和3.02kg;液氮保存期110h和116h.真空寿命达2年以上.接探测腔后,Ⅱ型杜瓦液氮保存期为40h;CCD冷盘温度可达到-100~-120℃. his article sums up the demand of cryogenically cooled dewars for astronomical CCD detector. The general situation of the dewars in China, the characteristics of the TWD type dewar and its test are described. The test results show that Mark Ⅱ and Mark Ⅲ dewars vessel without detector achieve the technical targets as follows:effective volume 2.5L and 1.25L, mass 2.05kg and 3.02kg, preservation time of liquid nitrogen 110h and 116h respectively. Vacuum keeping for more than two years. After connecting with detector, the preservation time of Mark Ⅱ dewars for liquid nitrogen is 40h, the temperature of CCD cold plate achieves-100~-120℃.
机构地区 兰州物理研究所
出处 《中国空间科学技术》 CSCD 北大核心 1995年第1期47-52,共6页 Chinese Space Science and Technology
关键词 电荷耦合器件 微光探测器 液氮杜瓦 制冷装置 Astronomical deware,Charge coupled device,Detector,Performance test