应用相差显微镜检测105例血尿标本的红细胞形态变化。按尿中红细胞形态的变化百分比分为三类:①变形红细胞>50%或以其为主的血尿为肾小球性血尿;②正常红细胞>50%或以其为主的血尿为非肾小球性血尿;③上述两种类型各占50%时称混合性血尿。其中肾小球性血尿(GH)53例与临床诊断符合率为94.3%,非肾小球性血尿(NGH)52例,诊断符合率为92.3%。本法操作简便、快速,可靠性高达90%以上,可做为临床血尿患者筛选常规之一。
The red cell morphalogic changes were examined with
phase-microscope in 105 hematuria samples.The hematuria were classlfied into ttlree
typesaccording to the percentage of distorted red cells :(1)glomerular hematuria in which
thepercentage of distorted red cells was higher than 50%, (2)nonglomerular hematuria inwhich
the percentage of normal cells was higher than 50%,(3)mixed hematuria in whichboth the
percentage of distorted red cell and normal red cell were 50%. The clinicaldiagnostic
coincidence in 53 cases of glomerular hematuria was 94.3%and 52 cases ofnonglomerular
hematuria 92.3%. This method is easy,quick and reliable;its reliabilitywas higher than 90%. It
may be used as one of the routine methods for screeninghematuria .