摘要
本文阐述了地铁轨枕等杂散电流的截流子性质 ,以及在混凝土中掺加粉煤灰对地铁等杂散电流腐蚀的抑制作用、机理。杂散电流作为离子流 ,它能破坏钢筋的表面钝化膜 ,促进钢筋的锈蚀。在混凝土中掺用粉煤灰抑制了钢筋表面钝化膜的破坏 ,从而降低了钢筋的杂散电流腐蚀。