摘要
对压缩机的湿气体级间冷却器冷凝水的问题进行了详细的分析,确定了冷却器中是否存在冷凝水析出的判别式,给出了级间冷却器中析水量的计算实例,结果表明计算值与实测值一致。
Condensed water of interstage cooler for the wet gas in the compressor was analyzed in detail,and the discriminant of condensed water in the interstage cooler is determined. An example is given to calculate the amount of condensed water in the interstage cooler.Results show that the calculated value is consistent with the measured values.
出处
《压缩机技术》
2014年第3期14-16,共3页
Compressor Technology
基金
国家重大科技专项(2011ZX05054)
关键词
压缩机
级间冷却器
析水量
compressor
interstage cooler
amount of condensed water