目的:探讨溶血对血凝结果测定的影响。方法:收集住院患者标本100例,进行凝血酶原时间(PT)、活化部分凝血活酶时间(APTT)、凝血酶时间(TT)和纤维蛋白原(Fbg)测定。结果:溶血组与溶血重抽复测组(非溶血组)PT、APTT、TT测定结果的差异具有统计学意义(P<0.05),Fbg测定结果的差异无统计学意义(P>0.05)。结论:临床检测中标本溶血对凝血结果的检测有干扰,建议重抽复测。
Objective:To investigate the influence of hemolysis on coagulation tests. Methods:100 hemolytic samples are collected,to measure plasma coagulation time and contents. Results:There are statistic significances (P〈0.05)for PT,APTT,TT testing results between hemolytic group and no hemolysis group (retesting group of drawing blood once more)There is no statistic significance (P〉0.05)for Fbg testing results between hemolytic group and no hemolysis group.Conlusion:There are influences about coagulation testing results to hemolytic samples. Drawing blood once more and retesting are suggested.
出处
《安徽卫生职业技术学院学报》
2014年第3期98-98,114,共2页
Journal of Anhui Health Vocational & Technical College