影响常压储罐底板漏磁检测可靠性的因素研究 被引量:1

Study on Impact Factors for the Reliability of Magnetic Flux Leakage Testing of Atmospheric Tank Floor
在线阅读 下载PDF
导出
摘要 通过对影响常压储罐底板漏磁检测可靠性的因素进行研究,希望能帮助业主及检测人员充分理解限制因素从而能够对于漏磁检测技术的局限性有更深刻的认识,只要合理应用漏磁检测技术并且充分理解其局限性,加上漏磁检测技术的可靠、快速没有任何其它技术可以比拟,那么储罐底板漏磁检测技术仍然是一种高效、较高精度的针对底板腐蚀减薄状况进行检测的面扫查技术,并且正逐渐应用于立式储罐底板的腐蚀状况安全评估过程。 In order to fully understand the limiting factors of the magnetic flux leakage inspection technique, impact factors for the reliability of magnetic flux leakage testing of atmospheric tank floor were studied. The results show that the magnetic flux leakage inspection technique is better than other techniques in the aspects of reliability and rapidity, the magnetic flux leakage inspection technique is still a highly effective, high precision inspection method for floor corrosion, and gradually applied into safety assessment process for corrosion of the vertical atmospheric tank floor.
出处 《辽宁化工》 CAS 2014年第6期812-814,共3页 Liaoning Chemical Industry
关键词 储罐 底板 漏磁 腐蚀 可靠性 storage tank floor MFL corrosion reliability
  • 相关文献

参考文献4

二级参考文献32

  • 1王勇,沈功田,李邦宪,闫河.压力容器无损检测——大型常压储罐的无损检测技术[J].无损检测,2005,27(9):487-490. 被引量:26
  • 2张吉泉,王震宇,卢启春,梁海辰,柳岩,陈新奎.立式原油罐底板腐蚀原因分析及解决方法[J].油气储运,2006,25(11):45-46. 被引量:8
  • 3杨鹏,黄松岭,赵伟,赵志刚,董甲瑞.便携式储罐底板漏磁检测器的研制[J].石油化工设备,2007,36(3):1-4. 被引量:5
  • 4Miller Ronnie K, Mclntire Paul. American Society for Nondestructive Testing. Acoustic Emission Testing. In: Nondestructive Testing Handbook [M]. Columbus: American Society for Nondestructive Testing, 1987.
  • 5Drouillard T. Acoustic Emission: A Bibliography with Abstracts[M]. New York: IFI Plenum Data Company, 1979.
  • 6Drouillard TF. Acoustic emission-the first half century [C].//The Japanese Society for NDI. Progress in A- coustic Emission Ⅶ. Sapporo: [s. n], 1994.
  • 7Van de, Loo PJ. How reliable is acoustic emission (AE) tank testing. The quantified results of an AE user group correlation study [C]// 7th European Conference on Nondestructive Testing. Copenhagen: [s. n. ],1998.
  • 8Ronnie K M. Tank-bottom leak detection in aboveground storage tanks by using acoustic emission[M]. [S. I.] Physical Acoustics Ltd, 1993:823--829.
  • 9Ichizo Uetake, Tetsuya Saito. Magnetic flux leakage by adjacent parallel surface slots[J]. NDT & E International, 1997,30(6) : 371-376.
  • 10Zhongqing You, David Bauer. Combining eddy current and magnetic flux leakage for tank floor inspection[J]. Materials Evaluation, 1994, 52 (7):816- 818.

共引文献21