摘要 采用冷等离子体模式,以^63Cu为内标,研究了单点激光剥蚀电感耦合等离子体质谱法(LA-ICP-MS)测定纯铜及铜丝中各元素的方法。优化了仪器参数;给出了样品直径对结果的影响,锌的信号随着直径的减小而减弱,硒的信号随着直径的减小而增强;研究了分馏效应,Cd,Sb,Pb,Bi分馏因子(FI)在0.80左右有分馏效应;采用不同系列铜标准物质制作了校准曲线以考察基体效应,Mn,Ni,Zn,Pb,Bi的线性相关系数大于0.99,基体效应不明显,其它元素有基体效应。建立了测定纯铜及铜丝中P,Mn,Fe,Ni,Zn,As,Se,Ag,Cd,Sn,Sb,Pb,Bi等元素的直接测定方法,但硫不能测定,也不能用56Fe作为铁的检测同位素,标准物质的测定值与认定值基本吻合,除Mn含量低外,其它元素的RSD(n=5)在2.1%~16%之间。 In cool plasma mode,^63Cu was used as an internal standard,and a method for the determination of elements in pure copper and its wire with single point laser ablation inductively coupled plasma mass spectrometry was investigated.Experimental parameters were optimized.The results from different diameter samples were provided,the zinc signal became smaller with decrease of the diameter,and the selenium signal became bigger with reduction of the diameter.The fractionation factors of Cd,Sb,Pb and Bi were about 0.80,so there was fractionation effect.Matrix effect was investigated through element calibration curves fitted by different matrix CRMs,and the correlation coefficients of Mn,Ni,Zn,Pb and Bi were largerthan 0.95,matrix effect was not obvious,but for other elements there was matrix effect.A method was proposed for the direct determination of elements P,Mn,Fe,Ni,Zn,As,Se,Ag,Cd,Sn,Sb,Pb and Bi in pure copper and its wire,but sulfur could not be analyzed,and iron could not be analyzed with m/z 56,either.Good agreement was achieved between the found levels and the certified values.Except low content manganese,RSDs(n = 5) were between 2.1 and 15.5 percent.
出处 《分析试验室》 CAS CSCD 北大核心 2014年第7期787-790,共4页 Chinese Journal of Analysis Laboratory
基金 国家质检总局项目(2012IK043) 宁波市自然科学基金项目(2012A610150)资助
关键词 激光剥蚀 电感耦合等离子体质谱法 纯铜 铜丝 Laser ablation Inductively coupled plasma mass spectrometry Pure copper Copper wire
  • 相关文献

参考文献10

  • 1胡芳菲,王长华,刘英,李继东.激光剥蚀-电感耦合等离子体质谱法测定多晶硅中杂质元素[J].分析试验室,2013,32(1):78-81. 被引量:5
  • 2金献忠,陈建国,杨文潮,潘炜娟.激光烧蚀-电感耦合等离子体质谱法测定塑料中的Pb、Cd、Cr和Hg[J].分析试验室,2010,29(3):72-75. 被引量:5
  • 3Hans-Rudolf Kuhn, Detlef Gulnther. Anal Chem, 2003, 75 : 747.
  • 4Liu C, Mao X L, Mao S S, et al. Anal Chem, 2004, 76 : 379.
  • 5Bian Q Z, Carmen C. Garcia, Joachim Koch and Kay Niemax. J Anal At Spectrom, 2006, 21 : 187.
  • 6Heike Traub, Markus Wille, Joachim Koch, et al. Anal Bioanal Chem, 2009, 395 : 1471.
  • 7Damian Waiaszek, Marianne Senn, Markus Failer, et al. Spectrochim Acta Part B, 2013, 79 -80:17.
  • 8Pattberg S, Matschat R. Fresenius J Anal Chem, 1999, 364:410.
  • 9Fryer B J, Jackson S E, Longefich H P. Can Mineral, 1995, 33:303.
  • 10西尔维斯特.地球科学中的激光剥蚀-ICPMS原理和应用.北京:地质出版社,2003.80.

二级参考文献30

共引文献9

同被引文献19

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部