彩色多普勒超声在血透动静脉内瘘功能评估中的应用 被引量:16

Oapplication of Color Doppler Ultrasonography in Diagnosis and Monitoring Function of Autologus Arterio-venous Fistula for Hemodialysis
暂未订购
导出
摘要 目的:探讨总结彩色多普勒超声在自体血管动静脉内瘘功能评估中的临床应用价值。方法:运用彩色多普勒超声技术检测自体血管动静脉内瘘功能。结果:716例自体血管动静脉内瘘中514例内瘘功能正常,202例出现不同类型并发症。结论:彩色多普勒超声技术检测自体血管动静脉内瘘功能评估中有很好的临床应用价值。 Objective:To investigate the value of color Doppler ultrasonography in diagnosis and monitoring function of autologus arterio-venous arterio-venous fistula for Hemodialysis. Methods:Color Doppler ultrasonography was used to examine the function of auto-logus arterio-venous fistula. Results:In 716 cases, different complications correlated autologus arterio-venous fistula were detected in 202 cases and other 514 cases were normal. Conclusion:It is useful for color Doppler ultrasound to diagnose and monitor the complications of autologous arterio-venous fistula.
出处 《中国中西医结合肾病杂志》 2014年第5期417-420,I0004,共5页 Chinese Journal of Integrated Traditional and Western Nephrology
关键词 彩色多普勒超声 动静脉内瘘 自体血管 并发症 血液透析 Color Doppler ultrasonography Arterio-venous fistula Autologous arteriovenous fistula Function Hemodialy-sis
  • 相关文献

参考文献21

  • 1Brescia M J, Cimino JE, Appel K, et al. Chronic hemodialysis u- sing venipuncture and a surgically created arteriovenous fistual. N Engl J Med,1966,275(20) :1089 -1092.
  • 2阿勇,崔天蕾,金骊珠,付平.自体动静脉内瘘早期功能障碍临床分析[J].中国中西医结合肾病杂志,2011,12(2):165-166. 被引量:19
  • 3McCarley P, Wingard RL, Shyr Y, et al. Vascular access blood flow monitoring reduces access morbidity and costs. Kidney Int, 2001,60(3) :1164 - 1172.
  • 4Besarab A, Lubowski T, Frinak S, et al. Detecting vascular access dysfunction. ASAIO J, 1997,43 (5) : M539 - M543.
  • 5Bay WH, Henry ML, Lazarus JM, et al. Predicting hemodialysis acaess failure with color flow Doppler ultrasound dilution and du- plex u]trasonography. Am J Nephrol, 1998,18 ( 4 ) : 296 - 304.
  • 6Sands J, Glidden D, Mirand C. Hemodialysis access flow meas- urement. Comparison of ultrasound dilutiou and duplex. ASAIO J,1996,42(5) :M899 - M901.
  • 7高海港,苏光明,祝莉,夏隽.超声对血液透析动静脉内瘘常规监测中的应用价值[J].医学影像学杂志,2010,20(4):592-595. 被引量:15
  • 8Besarab A, Sherman R. The relationship of recirculation to access blood flow. Am J Kidney Dis, 1997,29 (2) : 223 - 229.
  • 9Lin PH, Bush RL, Nguyen L, et al. Anastomotic strategies to im- prove hemodialysis access patency - a review. Vasc Endovascular Surg,2005,39( 1 ) : 135 - 142.
  • 10张文贤,张训.血液透析患者血管通路血栓形成影响因素的分析[J].中华肾脏病杂志,2002,18(3):221-222. 被引量:49