期刊文献+

间二甲苯装置异构加热炉炉管剩余寿命计算

Remaining Life Evaluation for Furnace Tube of Isomerism Heating Furnace, MX Plant
在线阅读 下载PDF
导出
摘要 燕山石化公司化工八厂异构加热炉L-101为间二甲苯装置设备,迄今使用超过30年。为科学评价炉管剩余寿命,本文进行了炉管损伤机理分析,并通过在线红外热成像,依据API581确定了计算腐蚀速率。按照设计标准分别对对流段炉管和辐射段炉管进行了强度校核、蠕变强度校核和热应力校核,综合分析得到了炉管的剩余寿命。 A Isomerism heating furnace which belong to the eight chemical factory of Yanshan Co.,Ltd. SINOPEC had been used for thirty years. To assess its remaining life, the damage mechanism offurnace tube is analyzed, on-stream infrared temperature measure performed, the calculated corrosion rateis selected due to API581-2008, strength, thermal strength and creep strength is conformed. As a result,remaining life of furnace tube is worked out.
作者 曹立峰 高扬
出处 《全面腐蚀控制》 2014年第3期61-66,共6页 Total Corrosion Control
关键词 异构加热炉 炉管 损伤机理 蠕变 剩余寿命 Isomerism heating furnace furnace tube damage mechanism remaining life creep
  • 相关文献

参考文献1

  • 1SH/T 3037-2002 炼油厂加热炉炉管壁厚计算[S]. 北京, 中国标准出版社, 2002.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部