摘要
分析IMAX巨幕电影厅消防设计的突出问题。针对某工程实例,通过性能化设计的方式对IMAX巨幕电影厅安全性进行分析,得出IMAX巨幕电影厅消防设计难点的解决方法及建议。详细介绍拟采用的性能化设计目标及方案、设计方法及判据、火灾场景设定、安全性分析和安全疏散判定。
Problems of fire safety design in IMAX giant screen cinema were analyzed. Against an engineering example, the method of performance-based design was applied to solve the fire safety design problems. The performance-based design target and plan, method and criterion, fire scene design, safety analysis and evacuation assessment were introduced in details.
出处
《消防科学与技术》
CAS
北大核心
2014年第5期531-533,共3页
Fire Science and Technology
关键词
IMAX巨幕电影厅
性能化设计
消防设计
IMAX giant screen cinema
performance-based de-sign
fire safety design