期刊文献+

可视化角膜生物力学分析仪评估角膜生物力学特性的研究进展 被引量:10

Advances in corneal biomechanical properties of corneal visualization scheimpfl ug technology assessment
暂未订购
导出
摘要 可视化角膜生物力学分析仪(corneal visualization scheimpflug technology,Corvis ST)是一种联合Scheimpflug高速摄像和气冲印压技术测量角膜生物力学的新设备。该设备能够实时动态记录角膜受压形变的整个过程,记录形变过程参数分析角膜生物力学特性。本文就Corvis ST测量原理、操作方法、测量参数的可靠性和临床应用情况做一综述。 Corneal visualization scheimpflug technology (Corvis ST) is a new device that combines Scheimpflug high-speed camera with air-jet indentation system to measure the corneal biomechanics. Corvis ST can monitor the whole process of real-time dynamic corneal deformation, and record the deformation parameters to analyze the corneal biomechanical properties. Measurement principle and operation method, the reliability of parameters and clinical applications of Corvis ST are reviewed in this study.
作者 田磊 黄一飞
出处 《解放军医学院学报》 CAS 2014年第5期502-505,共4页 Academic Journal of Chinese PLA Medical School
基金 国家自然科学基金项目(81271052)~~
关键词 角膜生物力学 可视化角膜生物力学分析仪 眼内压 圆锥角膜 corneal biomechanics corneal visualization scheimpflug technology intraocular pressure keratoconus
  • 相关文献

参考文献23

  • 1Kwon TH,Ghaboussi J,Pecknold DA,et al.Role of corneal biomechanical properties in applanation tonometry measurements [ J ].J Refract Surg,2010,26(7):512-519.
  • 2Scheler A,Spoerl E,Boehm AG.Effect of diabetes mellitus on corneal biomechanics and measurement of intraocular pressure [ J ].Acta Ophthalmol,2012,90(6):e447-e451.
  • 3Kaushik S,Pandav SS,Banger A,et al.Relationship between corneal biomechanical properties,central corneal thickness,and intraocular pressure across the spectrmn of glaucoma [ J ].Am J Ophthalmol,2012,153(5):840-849.e2.
  • 4Prata TS,Lima VC,Guedes LM,et al.Association between corneal biomechanical properties and optic nerve head morphology in newly diagnosed glaucoma patients [ J ].Clin Experiment Ophthalmol,2012,40(7):682-688.
  • 5Kling S,Marcos S.Effect of hydration state and storage media on corneal biomechanical response from in vitro inflation tests [ J ].J Refract Surg,2013,29(7):490-497.
  • 6Hjortdal JO,Jensen PK.In vitro measurement of corneal strain,thickness,and curvature using digital image processing [ J ].Acta Opbthalmol Seand,1995,73(1):5-11.
  • 7Yang YF,Zhang J,Wang XH,et al.Simulation of corneal tissue mechanical deformation due to laser thermokeratoplasty:a finite element methods study [J ].Australas Phys Eng Sci Med,2009,32(4):220-225.
  • 8Luce DA.Determining in vivo biomechanical properties of the cornea with an ocular response analyzer[ J ].J Cataract Refract Surg,2005,31(1):156-162.
  • 9Mcmonnies CW.Assessing corneal hysleresis using the Ocular Response Analyzer [J].Optom Vis Sci,2012,89(3):E343-E349.
  • 10Liu J,He X,Pan X,et al UItrasonic model and system for measurement of comeal biomechanical properties and validation on phantons[J].J Biomech,2007,40(5):1177-1182.

同被引文献121

  • 1中华医学会眼科学分会眼视光学组,中国医师协会眼科医师分会眼视光专业委员会,中国医师协会眼科医师分会屈光手术专业委员会,吕帆,王雁,陈世豪,瞿佳,王勤美,张丰菊,周行涛.中国角膜交联术治疗扩张性角膜疾病专家共识(2023)[J].中华眼视光学与视觉科学杂志,2023,25(12):881-888. 被引量:10
  • 2Lackner, Birgit,Schmidinger, Gerald,Pieh, Stefan,Funovics, Martin A.,Skorpik, Christian.Repeatability and reproducibility of central corneal thickness measurement with pentacam, orbscan, and ultrasound. Optometry and Vision Science . 2005
  • 3Mustafa A. Anayol,Emre Güler,Ramazan Ya?c,Mehmet A. ?ekero?lu,Meltem Ylmazo?lu,Hakan Trh?,Ali E. Kulak,Pelin Ylmazba?.Comparison of Central Corneal Thickness, Thinnest Corneal Thickness, Anterior Chamber Depth, and Simulated Keratometry Using Galilei, Pentacam, and Sirius Devices[J]. Cornea . 2014 (6)
  • 4Tukezban Huseynova,George O. Waring,Cynthia Roberts,Ronald R. Krueger,Minoru Tomita.Corneal Biomechanics as a Function of Intraocular Pressure and Pachymetry by Dynamic Infrared Signal and Scheimpflug Imaging Analysis in Normal Eyes[J]. American Journal of Ophthalmology . 2014 (4)
  • 5Lukas Reznicek,Daniel Muth,Anselm Kampik,Aljoscha S Neubauer,Christoph Hirneiss.Evaluation of a novel Scheimpflug-based non-contact tonometer in healthy subjects and patients with ocular hypertension and glaucoma[J]. British Journal of Ophthalmology . 2013 (11)
  • 6Average 3-Dimensional Models for the Comparison of Orbscan II and Pentacam Pachymetry Maps in Normal Corneas[J]. Ophthalmology . 2009 (11)
  • 7Agreement and Repeatability of Central Thickness Measurement in Normal Corneas Using Ultrasound Pachymetry and the OCULUS Pentacam[J]. Cornea . 2005 (8)
  • 8Yaniv Barkana,Yariv Gerber,Uri Elbaz,Shulamit Schwartz,Gie Ken-Dror,Isaac Avni,David Zadok.Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry[J]. Journal of Cataract & Refractive Surgery . 2005 (9)
  • 9Nader G Iskander,Ellen Anderson Penno,N.Timothy Peters,Howard V Gimbel,Maria Ferensowicz.Accuracy of Orbscan pachymetry measurements and DHG ultrasound pachymetry in primary laser in situ keratomileusis and LASIK enhancement procedures[J]. Journal of Cataract & Refractive Surgery . 2001 (5)
  • 10A. Lopez-Miguel,J. C. Nieto,M. Diez-Cuenca.Agreement of non-contact pachymetry after LASIK: comparison of combined scanning-slit/Placido disc topography and specular microscopy. Eye . 2010

引证文献10

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部