摘要
发电机运行中的线圈温度、线圈出水温度是发电机安全运行的重要指标之一 ,因而要求温度测点能正确显示各部位的温度 ,真实地反映发电机的运行状况。文章从温度测点显示值异常情况中发现弓形引线堵塞的过程并且介绍了处理的步骤。
The temperatures of coil and its outlet water are important indexes for safe operation of the generator.The temperature measuring points are required to display correctly at each location in orderto monitor the running state of generator in right way.This paper introduces how to judge and dispose the blockage of bow outlet coil from the abnormal temperature values.
出处
《湖北电力》
2000年第4期46-47,共2页
Hubei Electric Power
关键词
汽轮发电机
温度测点
引线
堵塞
turbogenerator
temperature measuringpoint
outlet line
blockage