摘要
根据消防规范中设计水泵接合器的规定,结合设计的经验,阐述并探讨了水泵接合器在消防系统中的作用、分类、设置位置、与消防水池的距离、与室外消火栓数量的关系等,为合理设计消防水泵接合器提供参考。
According to the specification design of water pump adapter in fire fighting provisions, combining with the design experience, this pa- per elaborated and discussed the function, classification, location setting, distance to fire fighting water tank, relationship to outdoor fire hydrant quantity of water pump adapter in fire fighting system, provided reference for reasonable design of fire fighting pump adapter.
出处
《山西建筑》
2014年第13期140-141,共2页
Shanxi Architecture
关键词
消防
水泵接合器
室外消火栓
消防水池
fire fighting, water pump adapter, outdoor fire hydrant, fire fighting water tank