亚临界炉锅水pH降低原因分析及预防对策 被引量:2

An Analysis of the Causes of Boiler Water pH Value Reduction in a Subcritical Pressure Boiler and Some Measures Taken for Its Prevention
在线阅读 下载PDF
导出
摘要 通过对某电厂水质事故实例的分析 ,指出锅水pH降低的原因是由于混床树脂泄漏进入主系统造成 ,采用不锈钢梯形绕丝配水装置和负压反冲式树脂捕捉器可以预防这类事故发生。 In connection with a series of boiler water quality failures occurring at a certain power plant an analysis was conducted of the cause of the decrease in boiler water pH value. As a result, it is ascertained that the above cited decrease has been caused by the leakage of mixed bed resin into the main system. The use of a water distribution device equipped with stainless steel trapezoid shaped wound wires and a negative pressure reverse rinsing resin catcher has led to the prevention of the above mentioned failure.
作者 杨崇豪
出处 《热能动力工程》 CAS CSCD 北大核心 2001年第1期91-92,106,共3页 Journal of Engineering for Thermal Energy and Power
关键词 火电厂 水质事故分析 电站锅炉 亚临界 炉锅水PH值 thermal power plant, operation, accident analysis, feedwater, boiler water pH value
  • 相关文献

参考文献4

  • 1中国电力企业联合标准化部.电厂化学(中册),火电卷(6)[M].北京:中国电力出版社,1996..
  • 2杨崇豪,中国专利 :ZL972 0 92 14 .5,1998年
  • 3郑锡钩,中国专利 ZL 95224805.0,1996年
  • 4中国电力企业联合会标准化部,电力工业标准汇编,1996年

同被引文献2

引证文献2

二级引证文献1

相关作者