摘要 针对如何提高微型主动阀类压电泵的输出特性的问题,提出了主被动阀结合式压电泵的研究方案,并设计制作了压电泵,进行了试验研究。试验结果表明:主被动阀相结合式压电泵最大输出流量为520ml/min,最大输出压力25kPa。
作者 孙静 鲁海龙
出处 《科技创新与应用》 2014年第11期41-42,共2页 Technology Innovation and Application
基金 国家自然科学基金项目资助(50575093)
  • 相关文献

参考文献7

  • 1Ingo Ederer,Peter Raetsch,Wolfgang Schullerus,Carsten Tille,Ulrich Zech.Piezoelectrically driven micropump for on-demand fuel-drop generation in an automobile heater with continuously adjustable power output[J].Sensors & Actuators: A Physical.1997(1)
  • 2阚君武,杨志刚,程光明.压电泵的现状与发展[J].光学精密工程,2002,10(6):619-625. 被引量:58
  • 3Kan Junwu,Yang Zhigang,Peng Taijiang,Cheng Guangming,Wu Boda.Design and test of a high-performance piezoelectric micropump for drug delivery[J].Sensors & Actuators: A Physical.2004(1)
  • 4Jin-Ho Kim,C.J. Kang,Yong-Sang Kim.A disposable polydimethylsiloxane-based diffuser micropump actuated by piezoelectric-disc[J].Microelectronic Engineering.2003(2)
  • 5Tao Zhang,Qing-Ming Wang.Valveless piezoelectric micropump for fuel delivery in direct methanol fuel cell (DMFC) devices[J].Journal of Power Sources.2004(1)
  • 6赵爱玲,张海峰,王丙军.一种旋转压电陶瓷驱动器的设计和研究[J].机械设计与制造,2012(7):30-32. 被引量:4
  • 7曾平,程光明,刘九龙,杨志刚,郑丽兵.集成式计算机芯片水冷系统的研究[J].西安交通大学学报,2005,39(11):1207-1210. 被引量:23

二级参考文献44

  • 1秦振,阎绍泽.压电陶瓷驱动微小型步行机的设计与仿真研究[J].机械设计与研究,2004,20(4):15-17. 被引量:4
  • 2卢秋红,颜国正.基于粘-滑摩擦力模型的微型压电驱动器动力学分析[J].上海交通大学学报,2004,38(8):1328-1330. 被引量:3
  • 3鹿存跃,赵淳生.一种采用离合器耦合驱动的压电电机的设计[J].压电与声光,2005,27(1):24-26. 被引量:7
  • 4曾平,程光明,刘九龙,孙晓锋,赵艳龙.双腔薄膜阀压电泵的实验研究[J].光学精密工程,2005,13(3):311-317. 被引量:16
  • 5Woias P. Micropumps-summarizing the first two decades [J].SPIE, 2001,4560: 39-52.
  • 6Spencer W J, Corbett W T, Dominguez L R, et al. An electronically controlled piezoelectric insulin pump and valves [J]. IEEE Trans. Sonics Ultrasonbics, 1978, SU-25(3): 153-156.
  • 7van Lintel H T G, van de Pol F C M,Bouwstra S. A piezoelectric micropump based on micromachining of silicon [J]. Sensors and Actuators, 1988,15:153-167.
  • 8Linnemann R, Woias P, Senff C D, et al. A self-priming and bubble-tolerant piezoelectric silicon micropump for liquids and gases [A]. Proc. of the 11th IEEE MEMS 1998 Technical Digest[C]. Heidelberg, Germany, 25-29,1998: 532-537.
  • 9Mailefer D, van Lintel H, Mermet G R, et al. A High-performentce silicon micropump for an implantable drug delivery system [A]. Proc. of the 12th IEEE MEMS 1999 Technical Digest[C]. Orlando, Florida,USA, 1/17-21/99:541-546.
  • 10Shoji S, Nakagawa S, Esashi N. Micropump and sample-injector for integrated chemical analysis system [J]. Sensors and Actuators A, 1990,21-23:189-192.

共引文献81

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部