期刊文献+

血管介入机器人系统的手术评估

Evaluation of Vascular Interventional Robot System
暂未订购
导出
摘要 目的:评估血管介入机器人手术的可行性。方法选择20只成年雄性杂犬,开展左侧肾动脉和左侧椎动脉血管介入手术,对机器人手术系统的重要参数和指标进行记录、分析和评估。结果左侧肾动脉与左侧椎动脉造影均成功进行。整个实验过程用时30-60 min,平均(35±4) min,操作者未暴露在X射线下,整个实验过程安全可靠。结论血管介入机器人系统可有效辅助完成介入手术,达到了设计目的。 Objective To evaluate the feasibility of vascular interventional robot system. Methods Twenty adult male dogs were operated on the left renal artery and the left vertebral artery with vascular interventional robot system. The important data and parameters were recorded, analyzed and evaluated. Results The renal arteriography and vertebral angiography were performed successfully. The whole process took 30-60 minutes, 35±4 minutes on average. The surgeons were not exposed to X-ray. The whole surgery was safe and reliable. Conclusion The robot could effectively assist the surgeons to fulfill the endovascular interventional surgery, and the purpose of the robot system could be achieved.
作者 刘达 倪自强
出处 《组织工程与重建外科杂志》 2014年第1期19-21,共3页 Journal of Tissue Engineering and Reconstructive Surgery
关键词 血管介入手术 机器人系统 评估 Vascular interventional surgery Robot system Evaluation
  • 相关文献

参考文献4

  • 1Da L, Liu D. Accuracy experimental study of the vascular inter- ventioual surgical robot propulsive mechanism [C]// Complex Medical Engineering (CME), 2011 IEEE/ICME International Conference. Heilongjiang: IEEE,2011:412-416.
  • 2Antoniou GA, Riga CV, Mayer EK, et al. Clinical applications of robotic technology in vascular and endovascular surgery [J]. J Vasc Surg,2011,53(2):493-499.
  • 3Zhao D, Liu D. Clinical training technology for vascular interven- tional surgery robot system based on master-slave expansion [C]// Mechatronies and Automation (ICMA), 2012 International Conference. Chengdu: IEEE,2012:604-610.
  • 4Zhou W, Lin PH, Bush RL. Lumsden. Endovascular training of vascular surgeons: have we made progress [J]? Semin Vasc Surg, 2006,19(2):122-126.