期刊文献+

Design and performances of electromagnetic particle detector for LHAASO-KM2A 被引量:1

Design and performances of electromagnetic particle detector for LHAASO-KM2A
原文传递
导出
摘要 In the Large High Altitude Air Shower Observatory(LHAASO) project,the one kilometer square extensive air shower array(KM2A) is the the largest detector array in terms of effect ive area.It consists of 5635electromagnetic particle detectors(EDs) and 122 1 union detectors(MDs).Each ED is composed of 16 scintillator tiles readout by wavelength-shifting fibers that are bundled and attached by a 25 mm PMT.The design of the unit and its performances,such as photoelectron yield,time resolution and uniformity,are discussed in detail.An assembling scheme for the whole ED is established to guarantee the uniformity throughout all 16 tiles in a single ED and all EDs in mass production. In the Large High Altitude Air Shower Observatory(LHAASO) project,the one kilometer square extensive air shower array(KM2A) is the the largest detector array in terms of effect ive area.It consists of 5635electromagnetic particle detectors(EDs) and 122 1 union detectors(MDs).Each ED is composed of 16 scintillator tiles readout by wavelength-shifting fibers that are bundled and attached by a 25 mm PMT.The design of the unit and its performances,such as photoelectron yield,time resolution and uniformity,are discussed in detail.An assembling scheme for the whole ED is established to guarantee the uniformity throughout all 16 tiles in a single ED and all EDs in mass production.
出处 《Chinese Physics C》 SCIE CAS CSCD 2014年第3期31-38,共8页 中国物理C(英文版)
基金 Supportcd by NSFC(11175147)
关键词 LHAASO KM2A electromagnetic particle detector scintillator uniformity LHAASO KM2A electromagnetic particle detector scintillator uniformity
  • 相关文献

参考文献13

  • 1HE H H et al. (LHAASO collaboration). ICRC2009, Poland.
  • 2SHENG X D et al. (LHAASO collaboration). ICRC2011, China.
  • 3MA X H et al. (LHAASO collaboration). ICRC2011, China.
  • 4XIAO G et al. (LHAASO collaboration). ICRC2011, China.
  • 5HUANG J et al. (ASy collaboration). ICRC2009, Poland.
  • 6http://geant4.cern.ch.
  • 7Riggi S et al. Nuclear Instruments and Methods A, 2010, 624: 583.
  • 8Photomultiplier Tubes: Basics and Applications. Second Edition. Hamamatsu, 1999.
  • 9Adriani O et al. (L3 + C collaboration). Nuclear Instruments and Methods A, 2002, 488: 209.
  • 10Nagel M. Aspects of a fiber/scintillator-based EM-calorimeter, ILC workshop, 2005.

共引文献2

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部