针对杨村煤矿的动态无功补偿需求,分析了该煤矿的供电系统特点、功率因数和谐波现状,计算了无功和谐波补偿容量,对几种常见无功补偿方式的对比分析,确定了由静止无功发生器(STATCOM)和电容器FC相结合的补偿方式。通过Matlab/Simulink进行模拟仿真,验证了该动态无功补偿方案的有效性。
In order to achieve the requirements of dynamic reactive power compensation of Yangcun mine, analyzes the features of power system, power factors and harmonic current; calculates the reactive power capacity and harmonic compensation, and compares several common reactive compensation modes. Confirms the compensation method that combined with static var generator STATCOM and capacitor FC. Through the Matlab/ Simulink simulation, testifies the effectiveness of this dynamic reactive power compensation method.