导出
摘要 目的评价手卫生宣传教育对医护人员手卫生依从性的效果。方法采用ATP生物荧光检测和现场观察方法,对医院开展手卫生宣传教育活动前后医务人员手卫生依从性进行监测与评估。结果开展手卫生宣传活动后,医师的手卫生依从性从30.8%上升到64.6%,洗手正确率从75.0%上升到86.3%,手卫生合格率从73.4%上升到83.0%。护士的手卫生依从性从54.4%上升到88.4%,洗手正确率从83.8%上升到92.5%,手卫生合格率从82.6%上升到91.7%。结论通过开展手卫生宣传活动,提高了医务人员的手卫生依从性和手卫生质量。
出处 《中国消毒学杂志》 CAS 北大核心 2014年第2期180-181,共2页 Chinese Journal of Disinfection
  • 相关文献

参考文献5

二级参考文献24

共引文献158

同被引文献102

  • 1魏兰芬,陆龙喜,朱一凡,郑云燕,潘协商,林军明.固体过氧乙酸杀菌效果及毒性试验观察[J].中国消毒学杂志,2005,22(1):10-13. 被引量:13
  • 2Davidson CA, Griffith C J, Peters AC, et al. Evaluation of two methods for monitoring surface cleanliness - ATP bioluminescence and traditional hygiene swabbing [J]. Luminescence, 1999, 14 (1) :33 -38.
  • 3Alfa M J, Fatima I, Olson N. The adenosine triphosphate test is a rapid and reliable audit tool to assess manual cleaning adequacy of flexible endoscope channels [ J ]. Am J Infect Control,2013, 41 (3) :249 -253.
  • 4Hansen D, Benner D, Hilgenhoner M, et al. ATP measurement as method to monitor the quality of reprocessing flexible endo- scopes [J]. Ger Med Sci J, 2004,(2) :04.
  • 5Obee PC, Griffith C J, Cooper RA, et al. Real - time monitoring in managing the decontamination of flexible gastrointestinal endo- scopes [ J ]. Am J Infect Control,2005,33 (4) :202 - 206.
  • 6Fushimi R, Takashina M, Yoshikawa H, et al. Comparison of a- denosine triphosphate, microbiological load, and residual protein as indicators for assessing the cleanliness of flexible gastrointesti- nal endoscopes [ J]. Am J Infect Control, 2013,41 ( 2 ) : 161 - 164.
  • 7Alfa MJ, Olson N, Murray BL. Comparison of clinically relevant benchmarks and channel sampling methods used to assess manual cleaning compliance for flexible gastrointestinal endoscopes [ J]. Am J Infect Control ,2014,42 ( 1 ) : 1 - 5.
  • 8Marena C, Lodola L, Zecca M, et al. Assessment of handwash- ing practices with chemical and microbiologic methods: prelimi- nary results from a prospective crossover study [ J ]. Am J Infect Control, 2002,30 (6) :334 - 340.
  • 9Willis C1, Morley R, Westbury J,et al. Evaluation of ATP biolu- minescence swabbing as a monitoring and training tool for effec- tive hospital cleaning [J]. Brit J Infect Control,2007,8 (5) :17 -21.
  • 10Boyce JM, Havill NL, Dumigan DG, et al. Monitoring the effec- tiveness of hospital cleaning practices by use of an adenosine triphosphate bioluminescence assay[ J]. Infect Cont Hosp Epide- miol, 2009,30(7) :678 -684.